鑫鑫医疗
LABSTAR 60 Automated Blood Culture System
Bench-top 3-part WBC differential analyzer reporting 22 parameters from a 20 µL whole blood sample, with a 60-sample autosampler for continuous batch processing in clinical laboratories.
Highlights
- 3-part WBC differential separating lymphocytes, monocytes, and granulocytes
- 22 reportable parameters per sample including RBC, PLT, HGB, MCV, MCH, MCHC
- 60-sample continuous autosampler rack for unattended batch processing
- 20 µL whole blood aspiration volume suitable for pediatric and routine draws
- Four-reagent liquid-stable set with 18-month shelf life at 2 to 30 degrees Celsius
- CE-marked in vitro diagnostic instrument for clinical laboratory use
- Closed-tube sampling with EDTA-K2 and EDTA-K3 primary collection tubes
- Onboard QC with Levey-Jennings charts and Westgard rule monitoring
Technical Dossier
| Principle | Impedance cell counting |
|---|---|
| WBC Differential | 3-part (lymphocyte, monocyte, granulocyte) |
| Reportable Parameters | 22 parameters |
| Throughput | 60 samples/hour |
| Sample Volume | 20 µL whole blood |
| Autosampler Capacity | 60 samples per rack |
| Anticoagulant | EDTA-K2 or EDTA-K3 |
| Reagents | Diluent, lyse, cleanser, hemoglobin reagent |
| Reagent Shelf Life | 18 months at 2 to 30 degrees Celsius |
| Display | Touchscreen LCD |
| Certification | CE-marked |
| Data Interface | USB and LAN |
Product Detail
Are you looking for a blood culture system? LABSTAR 60 detects bacteria and fungi. It works with blood and sterile body fluids. Different capacities fit different labs. It is reliable and cost-effective.
It tops the list for 'China excellent medical products'. China Association of Medical Equipment (CAME) selects this list.is list.
Performance is nearly 100% close to top brand.
It won the 2nd prize of National Progress Award. Ministry of Science and Technology issued this award.
Number of bottles: 60 bottles.
Features:
Constant temperature culture. Swing oscillation culture.
Pre-setting culturing cycle and temperature. They can be modified in real time.
Random placement and removal is supported. It works for anonymous bottle culturing.
Modular design allows bottle number increasing.

Laboratory Applications & Suitabilitylity
LABSTAR 60 is for continuous microbial detection. It is for clinical blood culture workflows. 60-bottle capacity targets mid-volume labs. They need ongoing incubation and monitoring. Footprint is small. Per-run cost is low. Typical deployment environments include:
- Hospital microbiology labs processing routine and STAT blood culture orders. These come from inpatient and emergency departments.
- Reference and regional laboratories batch-processing cultures from multiple collection points. Random-access bottle loading is required.
- Public health and infectious disease screening facilities. culturing sterile body fluids alongside blood specimens.
- Pediatric and ICU units low-volume blood draws are common. Reliable detection from small sample volumes is critical.
Procurement & Selection Guidanceance
Capacity Planning
Map your lab's daily bottle volume against 60-bottle capacity. System supports random placement and removal. Technologists can load new bottles at any time. No need to wait for a full batch to complete. This is useful for irregular arrival patterns or overnight STAT requests. If your facility grows beyond 60 concurrent bottles, modular design allows incremental expansion. No full instrument replacement needed.ded.
Operational Workflow Considerations
- Continuous culture with real-time adjustment. Pre-set culturing cycles and incubation temperatures can be modified in real time. Labs can adapt protocols for slow-growing organisms or special specimen types. No need to interrupt ongoing runs.
- Anonymous bottle culturing: Random placement and removal supports workflows. Bottles may arrive before patient demographics are fully registered. This prevents delays in critical specimen processing.
- Swing oscillation incubation: Constant-temperature culture with continuous oscillation promotes microbial growth. It can reduce time-to-detection for fastidious organisms.
Regulatory & Import Documentationtion
This instrument is CE-marked for in vitro diagnostic use. Distributors and hospital procurement teams should confirm CE IVD documentation package. It must align with your target market's medical device registration requirements. For markets requiring additional local registration, documentation packages can be provided. Contact manufacturer before placing order. Confirm available registration dossiers and expected documentation lead times.mes.
Installation & Infrastructureture
Verify the following before delivery to ensure smooth installation.
- Bench space: Confirm adequate benchtop area for instrument plus external control computer. This includes monitor and PC tower shown in product image.
- Power supply: Confirm compatible voltage and power specifications for your facility. Available upon request.
- Data interface: System connects via USB and LAN. Verify your laboratory information system (LIS) compatibility before installation.
- Environmental conditions: Ensure stable room temperature and humidity within instrument's operating range. Available upon request.est.
Manufacturer Backing

Manufactured by Xinxin Medical
Clinical diagnostics manufacturer founded in 2009. Operating a 6,000 m² production facility in Nanjing. Class 100,000 cleanroom assembly lines. In-house calibration laboratory.
ISO 13485 quality system with CE IVD documentation. Prepared to streamline distributor registration and customs clearance. Products registered or under registration in over 30 countries.
Frequently Asked Questions
Request a Quote or Technical Consultation
Confirm pricing, lead time, documentation packages, and consumable supply for LABSTAR 60. Our team supports distributor registration and laboratory deployment planning.
Contact Supplier